Weidmüller
Power supplies DC-UPS
Weidmüller uninterruptible power supplies DC-UPS: Safe power supply for automation bridges mains failures for up to 30 minutes at 40 A.
Weidmüller's uninterruptible power supply (DC-UPS) means highly available 24V power supply for automation. A reliable DC-UPS avoids costly machinery and system downtime and keeps safety functions, process controls and communication up and running for a defined period of time. The maintenance-free buffer module is perfect for momentary interruptions in the range of several 100 milliseconds; depending on usage, customers get a lifetime of up to 10 years from the device. The UPS controller in connection with a battery module bridges longer mains failures safely and reliably. This module provides power up to 40 A for 30 minutes or 1 A for 30 hours, depending on your needs. The temperature-compensated charging feature ensures a long battery life. Five finely graded battery modules between 1.3 and 17 Ah ensure custom-fit usage. The Weidmüller DC-UPS can be installed adjacent to each other, so they take up only 66 mm of width in the cabinet. TÜV certification and the upcoming cURus, cULus approvals facilitate the use of these products around the world.Weidmüller is expanding its range of power supply products with the new DC-UPS uninterruptible power supply, which offers highly available 24V DC power supply for automation. The DC-UPS avoids costly machinery and system downtime during mains failure and keeps safety functions, process controls and communication up and going for a defined period of time. If a power outage occurs at the system input, the DC-UPS reliably provides 24V to the automated components without interruption for a pre-defined period of time. This way, machinery and systems can be switched to a defined status or even continue to operate without change. The maintenance-free buffer module is suitable for momentary interruptions in the range of several 100 ms and has a lifetime of up to 10 years depending on usage. The UPS controller in connection with a battery module bridges longer mains failures, supplying power of up to 40A for 30 minutes or 1A for 30 hours, depending on the need.
A complete DC-UPS system can be assembled with the UPS controller, the corresponding battery module and the primary power supply. The system provides "backup power" for automation components in the range of minutes or hours. The modular set-up facilitates division of the total load into "unsecured" and "secured" load circuits, so that smaller UPS can often be planned and utilised.
The UPS controllers from Weidmüller feature a comfortable status indicator and manifold settings for custom-fit usage. In addition to the three relay contacts, there are three active transistor outputs available to easily wire a superior monitoring unit. What is more, every signal output can be inverted for the ideal adaptation to the existing logic using a DIP switch. A control input to the battery lock (interlock) makes it possible to freely switch between the UPS and the battery, ensuring technicians can safely work on the controls during service calls. At only 66 mm wide, the DC-UPS module are placed directly adjacent to each other, saving space in the cabinet.
Weidmüller offers manifold battery modules from 1.3 to 17 Ah, equipped with high-quality, maintenance-free AGM VRLA batteries. The temperature sensors integrated into the battery module can be connected to the DC-UPS via the "temp" input. The DC-UPS then measures the battery temperature and automatically conducts charging voltage according to the temperature-compensated charging recognition, which maximises the battery lifetime. There is a charge indicator along with status and error indicators for quick error analysis. The UPS controllers are equipped with innovative charge and discharge monitors. Protective mechanisms against over-discharge and deep discharge, reverse polarity and power overload have been implemented.
There are currently five battery variants available for order (24V DC 1.3 Ah/ 3.4 Ah/ 7.2 Ah/ 12 Ah/ 17 Ah). The UPS controller, in both the 24V 20A/10A and 24V 40A variants, and the DC BUFFER 24V 20A buffer module are available in broad temperature ranges of -25 C to 70 C for installation without space between the units. For both variants of UPS controller, four LED visually notify the users on site of the following, among others: battery fill level (tricolour LED, 100% = green; <85% = yellow; <40% = red; <20% flashing red), buffers (yellow LED), alarm (red LED) and switched off (yellow LED). The three status signals (alarm/buffers/charge) can be transmitted for remote monitoring using no-voltage relay contacts and additional transistor outputs.
The ConnectPower DC-UPS facilitates the use of these products in different applications, supported by its TÜV certification and the upcoming international approvals (cURus, cULus).
Fig. 1: Weidmüller DC-UPS: The uninterruptible power supply bridges mains failure of up to 30 minutes at 40 A. Detail 1: The charge, status and error indicators facilitate quick error analysis. Detail 2: Different types of operation guarantee the optimal utilisation of battery power and flexible usage.
Weidmüller DC-UPS: The battery modules are equipped with maintenance-free AGM VRLA batteries. An integrated temperature sensor ensures the constant, accurate charging of the battery.
Weidmüller DC-UPS: You can reliably manage short interruptions of power of several 100 ms with the maintenance-free buffer module.